METHERM Microporous M 1000 Max — High-Strength Microporous Board, Max 1000°C

METHERM Microporous M 1000 Max high-strength fumed silica microporous board, max 1000°C. Flexural strength 0.13 MPa for vibration-exposed and mechanically loaded installations. Distributed by ThermalEast for buyers needing robust microporous insulation.

Buyer Brief

METHERM Microporous M 1000 Max is specified when mechanical robustness governs the installation — not minimum thermal conductivity. The "Max" grade achieves flexural strength of 0.13 MPa versus 0.12 MPa for standard M 1000, through higher reinforcing fibre loading. The trade-off: thermal conductivity is 0.021 W/(m·K) at 20°C and 0.040 at 800°C (vs 0.020 and 0.033 for M 1000). If the installation is mechanically benign and pure thermal performance is the criterion, specify standard M 1000 instead.

Spec Snapshot

PropertyUnitValue
Maximum service temperature°C1000
Thermal conductivity at 20°CW/(m·K)0.021
Thermal conductivity at 200°CW/(m·K)0.024
Thermal conductivity at 400°CW/(m·K)0.028
Thermal conductivity at 800°CW/(m·K)0.040
Flexural strengthMPa0.13
Compressive strengthMPa0.3
Fire classificationClass A1 (non-combustible)
Asbestos contentNone
CFC / HCFC contentNone
Machinable / sawableYes — standard tools
DensityContact for data sheet

Note: density is documented in the product data sheet. Request the current data sheet from ThermalEast for certified density, thermal conductivity test reports, and mechanical test results.

Use Cases

Kiln Car Deck Insulation. Kiln car decks in tunnel and shuttle kilns must support ware weight and survive repeated thermal cycling to 900–1000°C. M 1000 Max's higher flexural strength reduces breakage from forklift point loads and extends replacement intervals.

Vibration-Exposed Furnace Positions. Backup insulation near burner ports, blower systems, and conveyor drives is subject to crack propagation under sustained cyclic loading. M 1000 Max's higher fibre loading resists this failure mode better than standard M 1000.

Multi-Step Handling Installations. Boiler shell retrofits and modular furnace builds requiring panels to be fitted, trimmed, and re-handled impose bending loads that exceed standard-grade tolerance. M 1000 Max reduces waste from board damage during installation.

Furnace Door and Frame Components. Door panels and frame insulation subject to repeated mechanical cycling and occasional impact — in high-cycle shuttle kilns and continuous annealing lines — specify M 1000 Max over standard M 1000.

When to Choose M 1000 Max vs M 1000

Specify M 1000 Max when vibration, handling, or mechanical loading governs the installation. Specify standard M 1000 when the position is mechanically benign and minimum lambda is the priority. Specify M 1100 when service temperature exceeds 1000°C.